Altered Pace Long term Maganetic EC Motor
Item Brief
E-MAX motor is the unique made everlasting magnet synchronous motor dependent on the IEC norm. E-MAX PMSM will be used for subsequent era which need more vitality conserving solution. Exceed IE4 variable pace AC motor (IEC60034-thirty-two-2016).
E-MAX motor is the initial era of DBS EC motor. E-MAX has led to develop the following era of engineering in motor efficiency and functionality.
E-MAX motor include two collection:
E-Max commercial
IEC Body seventy one to ninety long term magnet synchronous motor integrated drive
E-Max CZPT
IEC Body seventy one to 132 everlasting magnet synchronous motor
E-Max Business series (ECI sequence)
Design | Frame | Rated | Output | Output | Greatest |
dimensions | torque | @1500rpm | @3000rpm | speed | |
(Nm)** | (kW) | (kW) | (rpm) | ||
T71ECI01X36 | seventy one | one.two | .two | .forty one | 3600 |
T71ECI02X36 | two.4 | .forty one | .82 | 3000 | |
T71ECI03X18 | 3.2 | .55 | – | 1800 | |
T90ECI03X36 | 90 | three.2 | .fifty five | one.1 | 3600 |
T90ECI05X30 | four.eight | .seventy five | one.five | 3000 | |
T90ECI07X18 | 7 | one.one | – | 1800 |
** The rated torque is primarily based on the motor cooling approach. The element torque please see info sheet.
E-Max Industrial Motor Push Operate
CW/CCW chooseCZPTt-stop terminal0-10VDC speed controlRS485 ModbusSpeed hand handle by adjustable resistanceSpeed feedback
E-Max CZPT sequence (EC collection)
Product | Body | Rated | Output | Output | Highest |
dimensions | torque | @15000rpm | @3000rpm | velocity | |
(Nm)** | (kW) | (kW) | (rpm) | ||
T71EC01X36 | 71 | one.two | .two | .41 | 3600 |
T71EC02X36 | 2.4 | .forty one | .eighty two | 3600 | |
T71EC03X36 | three.2 | .55 | one.one | 3000 | |
T90EC03X36 | ninety | three.2 | .55 | 1.one | 3600 |
T90EC05X36 | 4.8 | .75 | one.five | 3600 | |
T90EC07X36 | 7 | one.one | two.2 | 3600 | |
T100EC10X36 | a hundred | 9.5 | one.five | three | 3600 |
T100EC14X36 | fourteen | 2.two | four | 3600 | |
T100EC19X30 | 19.1 | 3 | 5.5 | 3000 | |
T132EC26X30 | 132 | 25.five | four | seven.5 | 3000 |
T132EC35X30 | 35 | 5.5 | eleven | 3000 | |
T132EC48X30 | forty seven.7 | seven.5 | fifteen | 3000 | |
T132EC59X30 | fifty eight.nine | nine.2 | 18.five | 3000 | |
T132EC70X30 | 70 | 11 | 22 | 3000 |
** The rated torque is primarily based on the motor cooling technique. The depth torque you should see information sheet.
Effectiveness course
E-MAX motor has ultra-high performance equally at entire load and light load. The flat efficiency curve can save more power when the motor generate the enthusiast or pump in HVAC discipline.
Compare to IE4 motor effectiveness course E-MAX
E-Max Commercial collection
** Program effectiveness contain the motor and travel performance.
E-Max CZPT collection
** Performance is only motor efficiency.
Model number nomenclature
T 90 EC 03 V 36 C2 B14 P T1
1 2 3 4 5 6 7 8 9 10
Position | Character | Description |
one | “T” | Item system |
2 | “90” | Frame dimension: IEC 90# |
3 | “EC” | EC: long term magnet motor ECI: long lasting magnet motor with integrated drvie |
4 | “03” | Rated torque |
5 | “V” | Cooling technique: |
G = CZPT purposes, with enthusiast and fan hood. IC411 | ||
V = Air flow programs, CZPT enthusiast and admirer hood. | ||
six | “36” | Greatest velocity: 3600 rpm |
seven | C2 | Electricity line relationship strategy: T1 = Terminal box on best T2 = Terminal box on NDE C1 = No terminal box, electricity line from housing C2 = No terminal box, power line from NDE |
eight | B14 | Mounting approach: B3, B14, B5, B34, B35 |
9 | P | P = Slid rail |
ten | T1 | Voltage code: T1: 3 section 360-440 V T2: 3 period 200-240 V S1: 1 period 200-240 V S2: 1 stage 115 V |
VFD thing to consider
PMSM have to travel by the VSD. The motor cannot hook up to the regular AC energy directly. The VSD can be the industrial generate with vector handle or PM motor control mode. VSD need to be established up the appropriate motor parameter (see below table). The detail parameters can be discover in the design information sheet.
Energy decide on consideration
The power and torque in over model list is the rated power or torque when the motor has not any cooling technique (IC410). If the motor cooled by the wheel or the load the motor energy can be bigger. The element working variety you should see detail design info sheet. Under chart is a sample to determine the electrical power at diverse cooling issue.
Technologies
- Seasoned on the fan, pump, compressor and motion software with long lasting magnet motor layout
- Motor design constructing and simulation, functionality calculation, sound optimization
- Motor materials database: silicon metal, magnet, copper, aluminum
- Large precision examination tools and instrument
Production and top quality management
- Automated winding machine to get much better consistency
- CZPTal test products
- Magnetic flux examining